Type S Platinum-Rhodium Thermocouple — LICHENGDA catalog configuration

ACCURATE TEMPERATURE SENSING

Type S Platinum-Rhodium Thermocouple

Type S Platinum-Rhodium Thermocouple. Review Type S input, protection tube, atmosphere and insertion.

Catalog reference: SENSORS-2

Selection questions and drawing checklist ↓

Factory DirectOEM & ODMMade to Drawing

SPECIFICATION STARTING POINT

Identify the required probe configuration

Type S thermocouple; match instrument input, polarity and connection system.

Use catalog reference SENSORS-2 with your drawing. The selection inputs below identify the information needed for a configuration-specific quotation.

CONFIGURATION AND SELECTION

Specify the Type S platinum-rhodium assembly

Identify the process atmosphere and the protection-tube arrangement for the platinum-rhodium sensing assembly. Include insertion, mechanical support and the Type S instrument input; the alloy designation does not define the finished probe limit.

Type S thermocouple assemblies use platinum-rhodium sensing with protection suited to the process. Atmosphere, insertion and connection exposure are part of the finished probe specification.

Specification inputs for Type S Platinum-Rhodium Thermocouple
Sensing circuitType S thermocouple; match instrument input, polarity and connection system.
Measuring requirementsState continuous and peak exposure, atmosphere, response and required tolerance.
Probe drawingDimension the sheath or protection tube, insertion datum, mounting and lead transition.

Confirm the dimensions, construction and operating ratings on the current drawing and quotation for catalog reference SENSORS-2. View the archived product information below for reference.

SELECTION AND ORDERING

Type S platinum-rhodium furnace probe selection

This Type S platinum-rhodium thermocouple reference requires a defined protection assembly and measuring duty. The furnace atmosphere, insertion and connection exposure are part of selecting the complete probe.

Catalog reference: SENSORS-2 · Original catalog specifications

How should I specify a Type S platinum-rhodium thermocouple?

State Type S explicitly and provide the continuous and peak temperature, furnace atmosphere, insertion depth and protection-tube drawing. Include the instrument input and requested accuracy or inspection documentation so the complete measuring assembly can be reviewed.

Can the combined S, R and B table be used as a Type S temperature rating?

No. The original table groups several thermocouple designations and protection arrangements. A value in that combined table does not establish the operating limit of this Type S assembly. Confirm the selected sensing element, protection material and duty together.

What is the difference between overall length and insertion depth?

Overall length describes the complete probe dimension; insertion depth locates the measuring tip inside the process from its mounting datum. Specify both, including the part exposed outside the furnace and the position of the terminal connection.

Drawing details for Type S Platinum-Rhodium Thermocouple

Information to include with this catalog reference
DetailWhat to provide
Furnace dutyAtmosphere, continuous temperature, peaks and thermal cycle
Protection assemblyTube material requirement, diameter, mounting and insertion
Measurement systemType S input, extension connection and requested documents

ARCHIVED PRODUCT INFORMATION

Description

Thermocouple

Length

Insertion Depth

Graduation

Thermometric

Specification

Thermal response

Category

300

150

Mark

Scope

Diam (mm)

Protection
tube material

Time T (s)

Single

350

200

S/ R /B

0~2500C

Φ16

Corundum
material

<150

Pt Rh30-Pt Rh6

400

250

Φ25

<360

Double

450

300

Φ16

<150

PtRh 30-Pt Rh6

550

400

Φ25

<360

Single Pt Rh 10-Pt

650

500

Φ16

<150

900

750

Φ25

<360

Double Pt Rh10-Pt

1150

1000

Φ16

<150

1250

1100

Φ25

<360

temperature sensor thermocouple is use of metal platinum (pt) resistance and temperature with a certain

functional relation of temperature sensor,Due to its high accuracy, large measuring range, good reproducibility

and stability, etc. That are widely used in medium temperature (-200 ℃ ~ 650 ℃) in the range of temperature

measurement.Diameter of protective tube4~20. Length according to user requirements

S-Type Platinum Rhodium Thermocouple — k type thermocouple sensor 1

S-Type Platinum Rhodium Thermocouple — High Temperature Sensor R S B Platinum Rhodium Type Ceramic Probe Thermocouple 2

S-Type Platinum Rhodium Thermocouple — High Temperature Sensor R S B Platinum Rhodium Type Ceramic Probe Thermocouple 3

Product Advantage

1:High temperature resistant ceramic base ,99% corundum tube
2: imported chip ,Micro Welding Technology
3: the installation method can be customized,degrees fast response speed the installation
4: High accuracy,High quality temperature measuring wire

Package

S-Type Platinum Rhodium Thermocouple — High Temperature Sensor R S B Platinum Rhodium Type Ceramic Probe Thermocouple 4

Product Advantage

1: High temperature resistant ceramic base

2: Imported chip

3: Temperature resistance 0-2500℃

4: The installation method can be customized

5: Degrees fast response speed the installation

6: Micro Welding Technology

7: High accuracy, High quality temperature measuring wire

8: 99% corundum tube

1:The positive electrode (SP) of the S-type thermocouple wire is made of platinum rhodium alloy, which contains 10% rhodium and 90% platinum. The negative electrode (SN) is pure platinum, hence commonly known as a single platinum rhodium thermocouple. The thermocouple has a long-term operating temperature of 1300 ℃ and a short-term operating temperature of up to 1600 ℃.

2:·The positive electrode (RP) of the R-type thermocouple wire is made of platinum rhodium alloy, which contains 13% rhodium and 87% platinum. The negative electrode (RN) is pure platinum, so it is commonly known as a single platinum rhodium thermocouple. The long-term use temperature is 1300 ° C, and the short-term use temperature can reach 1600 ° C

3:The positive electrode (BP) of the B-type thermocouple wire is made of platinum rhodium alloy, which contains 30% rhodium and 70% platinum. The negative electrode (BN) is a platinum rhodium alloy, which contains 6% rhodium and 94% platinum, hence commonly known as a dual platinum rhodium thermocouple. The long-term use temperature of this thermocouple is 1600 ℃, and the short-term use temperature can reach 1800 ℃.

Related Product Recommendation

S-Type Platinum Rhodium Thermocouple — product detail 5S-Type Platinum Rhodium Thermocouple — product detail 6S-Type Platinum Rhodium Thermocouple — product detail 7

S-Type Platinum Rhodium Thermocouple — product detail 8S-Type Platinum Rhodium Thermocouple — product detail 9S-Type Platinum Rhodium Thermocouple — product detail 10

S-Type Platinum Rhodium Thermocouple — product detail 11S-Type Platinum Rhodium Thermocouple — product detail 12S-Type Platinum Rhodium Thermocouple — product detail 13

Company Profile

LICHENGDA company profile and heating element manufacturing facilities

Xiamen Lichengda Precision Manufacturing Co., Ltd. was established in 2 0 1 2 year. It is a

comprehensive company integrating production, sales and technical service. the factory covers an

area of 5000m2, has nearly 100 employees. Applicable quality-system and product-compliance documentation must be confirmed for the quoted product, legal entity and current scope.

Main products : cartridge heater,Tubular heater, Flexible heater, cartridge heater,silicone heater

thermocouple, heating element, and other heating products. The factory introduced advanced

automatic control system and online quality,inspection system to ensure the stability and reliability of product quality

S-Type Platinum Rhodium Thermocouple —  10702 15

1. Qucik Response:Your inquiry will be replied within 24 hours. Response Rate over 90%
2. Smooth Communication: Well-trained and experienced staffs to answer all your inquires.
3. Sincere Service Attitude: Treat Customers As Friends. No Questions are Neglected.
4. OEM Accepted: Free Sample,We can customize your products to meet all your different requests.
5. Small MOQ: Small Amount wholesales are supported to meet your needs as well as large demands.
6. Fast Delivery: We have Reliable Forwarders with long term cooperation and Competitive Price.

Hot Tags: s type Platinum Rhodium Thermocouple, China, manufacturers, suppliers, factory, wholesale, customized, cheap, in stock, free sample, Temperature Sensor Probe Thermocouple PT100, industrial waterproof rtd pt100 sensor, PT100 E K Type Thermocouple, Stainless Steel PT100 Rtd Thermocouple, thermocouple temperature sensor pt100, rtd thermocouple pt100 temperature sensor

Specifications and availability vary by configuration. Confirm dimensions, materials and electrical or measurement ratings in your quotation.

DRAWING AND QUOTATION REVIEW

Prepare the drawing for Type S Platinum-Rhodium Thermocouple

Use catalog reference SENSORS-2 with the dimensions and operating conditions for your order.

  • Sensing circuit: Type S thermocouple; match instrument input, polarity and connection system.
  • Measuring requirements: State continuous and peak exposure, atmosphere, response and required tolerance.
  • Probe drawing: Dimension the sheath or protection tube, insertion datum, mounting and lead transition.

The worksheet collects requirements; it is not a confirmed product specification or test certificate.

CONFIGURATION QUOTATION

Request this catalog configuration

Start with Type S Platinum-Rhodium Thermocouple. The quote form carries this catalog reference so you can add the dimensions and operating requirements for your order. Confirm the exact construction and ratings in the quotation.

Furnace probe selection →