ACCURATE TEMPERATURE SENSING
Type S Platinum-Rhodium Thermocouple
Type S Platinum-Rhodium Thermocouple. Review Type S input, protection tube, atmosphere and insertion.
Catalog reference: SENSORS-2
Selection questions and drawing checklist ↓
SPECIFICATION STARTING POINT
Identify the required probe configuration
Type S thermocouple; match instrument input, polarity and connection system.
Use catalog reference SENSORS-2 with your drawing. The selection inputs below identify the information needed for a configuration-specific quotation.
CONFIGURATION AND SELECTION
Specify the Type S platinum-rhodium assembly
Identify the process atmosphere and the protection-tube arrangement for the platinum-rhodium sensing assembly. Include insertion, mechanical support and the Type S instrument input; the alloy designation does not define the finished probe limit.
Type S thermocouple assemblies use platinum-rhodium sensing with protection suited to the process. Atmosphere, insertion and connection exposure are part of the finished probe specification.
| Sensing circuit | Type S thermocouple; match instrument input, polarity and connection system. |
|---|---|
| Measuring requirements | State continuous and peak exposure, atmosphere, response and required tolerance. |
| Probe drawing | Dimension the sheath or protection tube, insertion datum, mounting and lead transition. |
Confirm the dimensions, construction and operating ratings on the current drawing and quotation for catalog reference SENSORS-2. View the archived product information below for reference.
SELECTION AND ORDERING
Type S platinum-rhodium furnace probe selection
This Type S platinum-rhodium thermocouple reference requires a defined protection assembly and measuring duty. The furnace atmosphere, insertion and connection exposure are part of selecting the complete probe.
Catalog reference: SENSORS-2 · Original catalog specifications
How should I specify a Type S platinum-rhodium thermocouple?
State Type S explicitly and provide the continuous and peak temperature, furnace atmosphere, insertion depth and protection-tube drawing. Include the instrument input and requested accuracy or inspection documentation so the complete measuring assembly can be reviewed.
Can the combined S, R and B table be used as a Type S temperature rating?
No. The original table groups several thermocouple designations and protection arrangements. A value in that combined table does not establish the operating limit of this Type S assembly. Confirm the selected sensing element, protection material and duty together.
What is the difference between overall length and insertion depth?
Overall length describes the complete probe dimension; insertion depth locates the measuring tip inside the process from its mounting datum. Specify both, including the part exposed outside the furnace and the position of the terminal connection.
Drawing details for Type S Platinum-Rhodium Thermocouple
| Detail | What to provide |
|---|---|
| Furnace duty | Atmosphere, continuous temperature, peaks and thermal cycle |
| Protection assembly | Tube material requirement, diameter, mounting and insertion |
| Measurement system | Type S input, extension connection and requested documents |
ARCHIVED PRODUCT INFORMATION
Description
|
Thermocouple |
Length |
Insertion Depth |
Graduation |
Thermometric |
Specification |
Thermal response |
|
|
Category |
300 |
150 |
Mark |
Scope |
Diam (mm) |
Protection |
Time T (s) |
|
Single |
350 |
200 |
S/ R /B |
0~2500C |
Φ16 |
Corundum |
<150 |
|
Pt Rh30-Pt Rh6 |
400 |
250 |
Φ25 |
<360 |
|||
|
Double |
450 |
300 |
Φ16 |
<150 |
|||
|
PtRh 30-Pt Rh6 |
550 |
400 |
Φ25 |
<360 |
|||
|
Single Pt Rh 10-Pt |
650 |
500 |
Φ16 |
<150 |
|||
|
900 |
750 |
Φ25 |
<360 |
||||
|
Double Pt Rh10-Pt |
1150 |
1000 |
Φ16 |
<150 |
|||
|
1250 |
1100 |
Φ25 |
<360 |
||||
temperature sensor thermocouple is use of metal platinum (pt) resistance and temperature with a certain
functional relation of temperature sensor,Due to its high accuracy, large measuring range, good reproducibility
and stability, etc. That are widely used in medium temperature (-200 ℃ ~ 650 ℃) in the range of temperature
measurement.Diameter of protective tube4~20. Length according to user requirements



Product Advantage
1:High temperature resistant ceramic base ,99% corundum tube
2: imported chip ,Micro Welding Technology
3: the installation method can be customized,degrees fast response speed the installation
4: High accuracy,High quality temperature measuring wire
Package

Product Advantage
1: High temperature resistant ceramic base
2: Imported chip
3: Temperature resistance 0-2500℃
4: The installation method can be customized
5: Degrees fast response speed the installation
6: Micro Welding Technology
7: High accuracy, High quality temperature measuring wire
8: 99% corundum tube
1:The positive electrode (SP) of the S-type thermocouple wire is made of platinum rhodium alloy, which contains 10% rhodium and 90% platinum. The negative electrode (SN) is pure platinum, hence commonly known as a single platinum rhodium thermocouple. The thermocouple has a long-term operating temperature of 1300 ℃ and a short-term operating temperature of up to 1600 ℃.
2:·The positive electrode (RP) of the R-type thermocouple wire is made of platinum rhodium alloy, which contains 13% rhodium and 87% platinum. The negative electrode (RN) is pure platinum, so it is commonly known as a single platinum rhodium thermocouple. The long-term use temperature is 1300 ° C, and the short-term use temperature can reach 1600 ° C
3:The positive electrode (BP) of the B-type thermocouple wire is made of platinum rhodium alloy, which contains 30% rhodium and 70% platinum. The negative electrode (BN) is a platinum rhodium alloy, which contains 6% rhodium and 94% platinum, hence commonly known as a dual platinum rhodium thermocouple. The long-term use temperature of this thermocouple is 1600 ℃, and the short-term use temperature can reach 1800 ℃.
Related Product Recommendation









Company Profile

Xiamen Lichengda Precision Manufacturing Co., Ltd. was established in 2 0 1 2 year. It is a
comprehensive company integrating production, sales and technical service. the factory covers an
area of 5000m2, has nearly 100 employees. Applicable quality-system and product-compliance documentation must be confirmed for the quoted product, legal entity and current scope.
Main products : cartridge heater,Tubular heater, Flexible heater, cartridge heater,silicone heater
thermocouple, heating element, and other heating products. The factory introduced advanced
automatic control system and online quality,inspection system to ensure the stability and reliability of product quality

1. Qucik Response:Your inquiry will be replied within 24 hours. Response Rate over 90%
2. Smooth Communication: Well-trained and experienced staffs to answer all your inquires.
3. Sincere Service Attitude: Treat Customers As Friends. No Questions are Neglected.
4. OEM Accepted: Free Sample,We can customize your products to meet all your different requests.
5. Small MOQ: Small Amount wholesales are supported to meet your needs as well as large demands.
6. Fast Delivery: We have Reliable Forwarders with long term cooperation and Competitive Price.
Hot Tags: s type Platinum Rhodium Thermocouple, China, manufacturers, suppliers, factory, wholesale, customized, cheap, in stock, free sample, Temperature Sensor Probe Thermocouple PT100, industrial waterproof rtd pt100 sensor, PT100 E K Type Thermocouple, Stainless Steel PT100 Rtd Thermocouple, thermocouple temperature sensor pt100, rtd thermocouple pt100 temperature sensor
Specifications and availability vary by configuration. Confirm dimensions, materials and electrical or measurement ratings in your quotation.
DRAWING AND QUOTATION REVIEW
Prepare the drawing for Type S Platinum-Rhodium Thermocouple
Use catalog reference SENSORS-2 with the dimensions and operating conditions for your order.
- Sensing circuit: Type S thermocouple; match instrument input, polarity and connection system.
- Measuring requirements: State continuous and peak exposure, atmosphere, response and required tolerance.
- Probe drawing: Dimension the sheath or protection tube, insertion datum, mounting and lead transition.
The worksheet collects requirements; it is not a confirmed product specification or test certificate.
CONFIGURATION QUOTATION
Request this catalog configuration
Start with Type S Platinum-Rhodium Thermocouple. The quote form carries this catalog reference so you can add the dimensions and operating requirements for your order. Confirm the exact construction and ratings in the quotation.
Furnace probe selection →