ACCURATE TEMPERATURE SENSING
Type K Surface Thermocouple
Type K Surface Thermocouple. Specify the surface contact, attachment and ambient conditions.
Catalog reference: SENSORS-165
Selection questions and drawing checklist ↓
CONFIGURATION AND SELECTION
Measure a surface rather than the surrounding air
Mark the exact surface measuring point and the attachment arrangement. Include surface material, movement and ambient exposure so contact quality and the lead path can be assessed together.
Type K thermocouple selection starts with the measuring location and compatible instrument input. Define the probe construction for that point rather than transferring a temperature range from another assembly.
| Sensing circuit | Type K thermocouple; match instrument input, polarity and connection system. |
|---|---|
| Measuring requirements | State continuous and peak exposure, atmosphere, response and required tolerance. |
| Surface measuring point | Show contact location, attachment, surface material and ambient exposure. |
Confirm the dimensions, construction and operating ratings on the current drawing and quotation for catalog reference SENSORS-165. View the archived product information below for reference.
SELECTION AND ORDERING
Type K surface thermocouple contact selection
This surface thermocouple reference is for reviewing contact with the measured surface. Contact geometry, attachment and cable routing affect the installed measurement and should be specified with the sensor designation.
Catalog reference: SENSORS-165 · Original catalog specifications
How should I specify a Type K surface thermocouple?
Describe the measured surface, its curvature and the available attachment area. Provide a contact drawing and the operating temperature cycle. A surface probe measures at its contact point; its reading can differ from the temperature inside the part or in the surrounding air.
Are the copper patch and PT100 entries the same sensor configuration?
They are not a single electrical specification. The original information lists several patch arrangements and sensor designations, including PT100. For this Type K reference, identify the required contact shape and Type K connection together on the order drawing.
What cable details matter near a heated surface?
Show the lead exit direction and distance from the hot surface, then specify flexing, abrasion and the connection route. Confirm insulation and attachment for the local exposure rather than choosing cable solely from the temperature at the measuring contact.
Drawing details for Type K Surface Thermocouple
| Detail | What to provide |
|---|---|
| Contact geometry | Flat or curved surface, contact dimensions and attachment |
| Operating cycle | Surface temperature, movement and response requirement |
| Lead route | Exit direction, mechanical protection and Type K termination |
ARCHIVED PRODUCT INFORMATION
Description
The thermal conductivity is very good, and it can accurately measure the surface temperature of the object. It is to lead the wire directly after putting the temperature sensing element on the protection tube. Users can choose different indexing sleeve sizes and wire materials according to the different
temperature or the size of the measurement space. Generally used in small-scale temperature measurement occasions.
It seems like you're referring to a "patch thermocouple." A patch thermocouple is a type of temperature sensor that is designed to be attached to a surface to measure its temperature. These are often used in applications where it's important to monitor the temperature of a specific area without intrusive methods.
| Model | probe | range | |
| Pt100 | 20*7.5*3.6mm | -50 to 420℃ | |
| Resistance | Class A ,Class B | Precision | ±1℃,±2℃ |
| Wire material | Teflon/Silicone rubber (waterproof)/Glass fiber | ||


Key Features of Patch Thermocouples:
Surface Mounting: They are typically adhered or attached directly to the surface whose temperature needs to be measured.
Thin and Flexible: Patch thermocouples are usually thin and flexible, allowing them to conform to the shape of the surface.
Quick Response Time: Due to their design, they often have a fast response time to temperature changes.
Variety of Types: They can be made with different types of thermocouple materials (e.g., Type K, Type J, Type T) depending on the temperature range and environment.
Installation Tips:
Surface Preparation: Ensure the surface is clean and smooth for optimal adhesion and accurate readings.
Adhesive Selection: Use an appropriate adhesive that can withstand the temperature range and environmental conditions.
Placement: Position the patch thermocouple in a location that is representative of the area you want to measure.
|
Name |
patch thermocouple |
|
type |
K/E/J/T/PT100 |
|
Temperature |
0-600℃ (k),0-400℃ (E),-50-420℃ (PT100) |
|
patch materail |
copper |
|
inner diameter |
6mm,3mm,4mm,5mm,8mm,10mm,12mm,14mm,16mm,20mm |
|
wire length |
0.5m/1m/2m/3m or customzied |
|
Terminal |
U type Terminal or plug |
|
patch thickness |
0.8mm |

Product Advantage
1:High Precision Temperature control probe
2:Accurate measurement accuracy, high sensitivity, wide measurement range -200-600℃
3:Accurate measurement (imported chip)
4:fast response,anti-interference,Good temperature resistance


Types of Thermocouples:
Thermocouples are classified into different types based on the metal combinations used. Each type has a specific temperature range and application suitability:
Type K (Chromel-Alumel): Most common, suitable for a wide range of temperatures (-200°C to 1260°C).
Type J (Iron-Constantan): Used in reducing environments, range from -210°C to 1200°C.
Type T (Copper-Constantan): Ideal for cryogenic applications, range from -250°C to 400°C.
Type E (Chromel-Constantan): High output, suitable for cryogenic and moderate temperatures (-200°C to 900°C).
Type N (Nicrosil-Nisil): Stable at high temperatures, range from -270°C to 1300°C.
Type R/S (Platinum-Rhodium): Used for very high temperatures (up to 1600°C), often in laboratory settings.
Type B (Platinum-Rhodium): Suitable for extremely high temperatures (up to 1800°C).
Related Product Recommendation










Company Profile

Xiamen Lichengda Precision Manufacturing Co., Ltd. was established in 2 0 1 2 year. It is a
comprehensive company integrating production, sales and technical service. the factory covers an
area of 5000m2, has nearly 100 employees. Applicable quality-system and product-compliance documentation must be confirmed for the quoted product, legal entity and current scope.
Main products : cartridge heater,Tubular heater, Flexible heater, cartridge heater,silicone heater
thermocouple, heating element, and other heating products. The factory introduced advanced
automatic control system and online quality,inspection system to ensure the stability and reliability of product quality

1. Qucik Response:Your inquiry will be replied within 24 hours. Response Rate over 90%
2. Smooth Communication: Well-trained and experienced staffs to answer all your inquires.
3. Sincere Service Attitude: Treat Customers As Friends. No Questions are Neglected.
4. OEM Accepted: Free Sample,We can customize your products to meet all your different requests.
5. Small MOQ: Small Amount wholesales are supported to meet your needs as well as large demands.
6. Fast Delivery: We have Reliable Forwarders with long term cooperation and Competitive Price.
You may contact any one of our sales and services team: email to us as inquiry.
Hot Tags: k type surface thermocouple, China, manufacturers, suppliers, factory, wholesale, customized, cheap, in stock, free sample, k type pt100 thermocouples rtd, Bayonet Type J Thermocouple, 4 Wires Rtd Pt100 Thermocouple Sensor, high temperature sensor thermocouple thread, thermocouple temperature sensor pt100, j type screw industry thermocouple
Specifications and availability vary by configuration. Confirm dimensions, materials and electrical or measurement ratings in your quotation.
CONFIGURATION QUOTATION
Request this catalog configuration
Start with Type K Surface Thermocouple. The quote form carries this catalog reference so you can add the dimensions and operating requirements for your order. Confirm the exact construction and ratings in the quotation.
Junction selection →