DESIGNED FOR YOUR APPLICATION
240 V 400 W Hot Runner Coil Spring Heater
240 V 400 W Hot Runner Coil Spring Heater. Confirm the 240 V 400 W reference, nozzle fit and heated height.
Catalog reference: CUSTOM-72
Selection questions and drawing checklist ↓
CONFIGURATION AND SELECTION
Hot runner nozzle fit and sensing
Review the 240 V 400 W coil reference
Confirm that the named 240 V and 400 W combination matches the required duty. Supply the nozzle diameter, coil inside diameter and heated height; matching electrical figures alone does not establish mechanical equivalence.
Hot runner coil heaters are selected against the installed nozzle and mold drawing. The coiled dimensions, cold sections, lead exit and sensing arrangement belong to the same configuration review.
| Installed coil drawing | Specify nozzle outside diameter, coil inside diameter, heated height, pitch and winding direction. |
|---|---|
| Electrical and end layout | State voltage, power, cycle, cold sections, lead exit and retention. |
| Sensing arrangement | Identify integral or separate feedback, sensor type, measuring position and instrument input. |
Confirm the dimensions, construction and operating ratings on the current drawing and quotation for catalog reference CUSTOM-72. View the archived product information below for reference.
SELECTION AND ORDERING
240 V 400 W hot runner coil replacement inputs
The nominal 240 V and 400 W marking identifies the electrical reference for this hot runner coil. It does not establish nozzle fit, coil height, sensing or lead arrangement.
Catalog reference: CUSTOM-72 · Original catalog specifications
Are 240 V and 400 W enough to order this hot runner coil heater?
No. Add the nozzle diameter, required coil inside diameter, heated height, element cross-section, cold sections and lead exit. State the sensing arrangement and connection so the electrical rating can be matched to the installed geometry.
Can I replace this 240 V 400 W coil with another 400 W heater?
Matching wattage alone is insufficient. Compare nominal voltage, nozzle fit, heated zone, retention, lead position and feedback arrangement. A heater with the same power can have a different resistance, coil envelope or sensing location.
How should I request a different supply voltage for this coil configuration?
State the actual required voltage and wattage as a new electrical requirement, while supplying the installation drawing. Confirm the revised configuration and available space with the quotation. Do not treat the nominal 240 V reference as an automatic rating for another supply.
Drawing details for 240 V 400 W Hot Runner Coil Spring Heater
| Detail | What to provide |
|---|---|
| Nominal duty | 240 V / 400 W reference or an explicitly requested new rating |
| Coiled fit | Nozzle diameter, coil ID, heated height and retention |
| Installation interfaces | Lead exit, mold clearance, cold sections and sensing |
ARCHIVED PRODUCT INFORMATION
Description
Product Description
Hot runner coil heaters are made of nickel chrome resistance wire placed inside chrome nickel steel tube filled with MgO powder and compacted for faster and efficient heat transfer. The heaters are annealed to acquire malleability for bending into any shape. Hot runner heaters with built in thermocouple are also available. Hot runner bushes are produced with hot runner heaters of different cross section with inner brass and outer stainless steel cover.
|
Sheath Material |
stainless steel /brass |
Length Tolerance |
5% |
|
Insulation Material |
MgO |
Max.SheathTemp |
700°C |
|
Resistance Wire |
NiCr 80-20 |
Wattage Tolerance |
5% |
|
Thermocouple |
J-type; K-type |
Resistance Tolerance |
5% |
|
Die Electrical Strength |
800V A/C |
Dimensional Tolerance |
Coil I.D + 0.1~0.2mm |
|
Insulation |
>5MW |
Coil length +1mm |





Product advantage
1. Standard sizes available with various cross section
2. Various Watt Density options available.
3. Robust Design with Choice of Terminal Exits
4. Available with built in Thermocouple
5. Designed for even heat profile.
6. Precision fit on Hot Runner Nozzles & Manifolds.
7. Highly Non-corrosive.
8. Maximum heat transfer due to more contact area.
9. Advanced Thermal Engineering.


Company Information

Xiamen Lichengda Precision Manufacturing Co., Ltd. was established in 2 0 1 2 year. It is a
comprehensive company integrating production, sales and technical service. the factory covers an
area of 5000m2, has nearly 100 employees. Applicable quality-system and product-compliance documentation must be confirmed for the quoted product, legal entity and current scope.
Main products : cartridge heater,Tubular heater, Flexible heater, cartridge heater,silicone heater
thermocouple, heating element, and other heating products. The factory introduced advanced
automatic control system and online quality,inspection system to ensure the stability and reliability
of product quality
Certifications

1. Qucik Response:Your inquiry will be replied within 24 hours. Response Rate over 90%
2. Smooth Communication: Well-trained and experienced staffs to answer all your inquires.
3. Sincere Service Attitude: Treat Customers As Friends. No Questions are Neglected.
4. OEM Accepted: Free Sample,We can customize your products to meet all your different requests.
5. Small MOQ: Small Amount wholesales are supported to meet your needs as well as large demands.
6. Fast Delivery: We have Reliable Forwarders with long term cooperation and Competitive Price.
You may contact any one of our sales and services team: email to us as inquiry.
Hot Tags: 240v 400w industrial electric hot runner coil heater spring elements, China, manufacturers, suppliers, factory, wholesale, customized, cheap, in stock, free sample, Hot Runner Copper Coil Heaters, Electric Spring Hot Runner Brass Heater, Hot Runner Coil Spring Heater
Specifications and availability vary by configuration. Confirm dimensions, materials and electrical or measurement ratings in your quotation.
DRAWING AND QUOTATION REVIEW
Prepare the drawing for 240 V 400 W Hot Runner Coil Spring Heater
Use catalog reference CUSTOM-72 with the dimensions and operating conditions for your order.
- Installed coil drawing: Specify nozzle outside diameter, coil inside diameter, heated height, pitch and winding direction.
- Electrical and end layout: State voltage, power, cycle, cold sections, lead exit and retention.
- Sensing arrangement: Identify integral or separate feedback, sensor type, measuring position and instrument input.
The worksheet collects requirements; it is not a confirmed product specification or test certificate.
CONFIGURATION QUOTATION
Request this catalog configuration
Start with 240 V 400 W Hot Runner Coil Spring Heater. The quote form carries this catalog reference so you can add the dimensions and operating requirements for your order. Confirm the exact construction and ratings in the quotation.
Lead routing around hot runner systems →